- CIPD level 5HR02 Assignment: Talent Management and Workforce Planning Unit Guide
- Level 3 D/615/3823 Assignment: Regulation, Protection, and Collaborative Practice in Health and Social Care
- ILM Level 4 Assignment 01: Developing Leadership Styles: An Action Plan for Effective Leadership and Team Engagement
- Level 6 Unit T/615/2726 Assignment: Strategic Project Management: Identifying, Planning, and Controlling Projects for Business Success
- EDD-U1-T4 Assignment: Internal and External Support Services for Educational Practitioners
- Discussion Paper on Market Forces and Government Interventions for Business Leaders
- Unit 10 Customer Relationship Management Assignment – CRM Processes & Stakeholder Roles
- CIPD 7HR02 Resourcing and Talent Management to Sustain Success
- Athe Level 3 Health and Social Care Assessment Questions
- M/618/4168 Unit 2 Principles, Values and Regulation in the Health and Social Care Sector – ATHE Level 3
- ILM Communication Skills Self-Assessment
- ILM Unit 8600-309: Understand How to Establish an Effective Team
- CMI Unit 525 Using Reflective Practice to Inform Personal and Professional Development
- Understand and Work with a Wide Range of Stakeholders and Organisational Structures – Assignment 1
- Assessment: Financial Performance Evaluation of Savory Snacks Company Ltd for Credit
- CMI L5 Assignment: Managing Stakeholder Relationships: Strategies, Challenges, and Best Practices
- Level 3 Unit 2 Assignment: Principles, Values and Regulation in the Health and Social Care Sector
- COM4006 Assignment: Introduction to Academic Skills and Professional Development
- Assessment: Managing Organisational Change: Evaluating Strategies, Challenges, and Impact
- UNIT CMI 706 Assignment: Finance for Strategic Leaders: The Role, Scope, and Impact of Finance
BN2007: Propose, sketch and describe a heating system to be installed in this building justifying your choice: Building Services Integration, Assignment, UCLan, UK
University | University Of Central Lancashire (UCLan) |
Subject | BN2007: Building Services Integration |
Scenario
A 5-story office building is to be provided by mechanical, public health, and electrical systems. The building has the basement and top roof spaces available for plant allocation. You have been approached by the client from the outset to give advice on the integration of Mechanical and Electrical building services in this building. You are faced with the following duties to perform:
Mechanical HVAC Services
- Propose, sketch and describe a heating system to be installed in this building justifying your choice.
- Explain THREE factors that should be included in the decision on the position of the heat emitters. Give examples and illustrate your answer. What safety precautions must be taken in this building in areas occupied by disabled people?
- State, with reasons, the appropriate combinations of natural and mechanical ventilation for the toilets and basement boiler room areas in this building, support your answer with clear sketches where appropriate.
- It is found that if a high-level air supply system is used in this building there would not be enough space in the ceiling void (above the false ceiling) to accommodate ductwork and air supply boxes. Recommend a proposal on what alternative system should be used and why. Comment on all aspects that you may consider.
- If an air handling unit is allocated on the roof and the refrigeration plant is in the basement, by means of a clear sketch show how they are linked to each other. What builder’s work is needed to accommodate air distribution installation with regard to the shell and the core of the building? Can a heat pump system be used in this office block to replace the air conditioning and part of the central heating system? Justify your answer.
Do You Need Assignment of This Question
Electrical and Transportation Services :
- Prepare a site program for the main contractor for the installation and operation of temporary site electrical services for this building including the factors that should be taken into consideration?
Lighting provision
- Propose an artificial lighting system for one typical floor. Explain the reason(s) for your choice.
- How can your proposal contribute to a “sustainable building design” and how can it be integrated with the provision of daylight to minimize the use of electrical lighting?
Fire and Security systems
If a sprinkler system is proposed in this building, explain how it functions, giving details of the alternative operating modes available and how it integrates with the building control system. State the suitable sources of water for sprinklers.
Buy Answer of This Assessment & Raise Your Grades
Looking for dependable online assignment writers in the UK? Your solution is here! At the University of Central Lancashire (UCLan), for the BN2007 Building Services Integration Assignment, trust Diploma Assignment Help UK. Our cheap assignment help in the UK ensures top-quality assistance without breaking the bank. Our expert team of writers is ready to guide you through the intricacies of your assignment, ensuring your success.